 NAN40 SERIES
Dual and triple output
* * * * * * 5.0 x 3.0 x 1.2 inch package (1U applications) Ideal for high volume designs Industry standard package Overvoltage and short circuit protection 40W with free air convection EN55022, EN55011 conducted emissions level B
The NAN40 series are 40W universal input AC/DC power supplies on a 5 x 3 inch card with a maximum component height of 1.2 inch for use in 1U applications. These series are available with a wide range of models in the industry standard 5 x 3 inch footprint at low cost making the series ideal for new and existing high volume communication and industrial applications. The NAN40 series provide 40W of output power with free air convection cooling with a peak output of 50W for a maximum duration of 60 seconds. The NAN40 series are designed for use in high volume low power data networking, computer and telecom applications such as hubs, routers, POS terminals, cable modems and PABX's. This list is not exclusive as the generic feature set of both series with industry standard output configurations provide a solution for most high volume applications including many industrial applications.
[ 2 YEAR WARRANTY ]
SPECIFICATION
OUTPUT SPECIFICATIONS Line regulation Total regulation Overshoot/undershoot Transient response Temperature coefficient Overvoltage protection Output power limit Short circuit protection
All specifications are typical at nominal input, full load at 25C unless otherwise stated EMC CHARACTERISTICS 0.5% 1.0% 3.0% 5.0% <10% 150mV max. dev., 500s recovery 0.02%/C Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 level B level A criteria 2 criteria 2 criteria 2 criteria 2 criteria 2 criteria 2
Main output Auxiliary outputs Main output Auxiliary outputs At turn-on +5.1V (1.5A to 3A step)
Perf. Perf. Perf. Perf. Perf. Perf.
GENERAL SPECIFICATIONS Hold-up time Efficiency Isolation voltage Switching frequency Approvals and standards (See Note 8) Weight MTBF MIL-HDBK-217F Input/output Input/chassis 110VAC 230VAC 10ms @ 40W 60ms @ 40W 68% min. @ 40W 3000VAC 1500VAC Variable VDE0805, EN60950, IEC950 BABT, IEC1010, UL1950 CSA C22.2 No. 950 200g (7.06oz) 150,000 Hours
+5.1V output Primary power limited Multiple output
6.25V 0.75Vout 50W Pout, min. 110W Pin, max. 30 seconds
INPUT SPECIFICATIONS Input voltage range Input frequency range Input surge current Safety ground leakage current 110VAC, cold start 230VAC, cold start 110VAC, 60Hz 230VAC, 50Hz Universal input 90 to 264VAC 120 to 370VDC 47Hz to 440Hz 15A 32A 0.2mA 0.4mA
ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating 0C to +70C Non-operating -40C to +85C 0C to 50C ambient, 40W convection cooled 50C to 70C, Derate linearly ambient conv. cooled to half load Peak (0C to 50C) max. 60s 50W Non-condensing Operating Non operating 5% to 95% RH 10,000 feet max. 30,000 feet max.
International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1076 Licence No. 70567, 1076 and 90354 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C Certificate No. PS/605108
Relative humidity Altitude Vibration
Three orthogonal axes, 2.4G rms random vibration, 10 5Hz to 500Hz minute test for each axis
PAGE 1
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
|
40W AC/DC
40 Watt AC/DC universal input switch mode power supplies
OUTPUT VOLTAGE + 5.1V (IA) +12V (IB) MAX 3A 2A
(1)
OUTPUT CURRENT PEAK 7A 3A
(2)
FAN 4A 2A
(3)
RIPPLE 50mV
(4)
TOTAL REG.
(5)
MODEL NUMBER NAN40-7608
(5)
(B)
3.0% 5.0%
120mV
-12V (IC)
+5.1V (IA) +12V (IB) -5V (IC) +5.1V (IA) +12V (IB)
0.35A
3A 2A 0.35A 3A 2A
1A
7A 3A 1.0A 7A 3A
0.5A
4A 2A 0.5A 4A 2A
120mV
50mV 120mV 50mV 50mV 120mV
5.0%
3.0% 5.0% 5.0% 3.0% 5.0% NAN40-7629
(5)
NAN40-7607
(5)
Notes
1 2 Natural convection cooling (40W maximum). Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation limits. Forced air, 20CFM at 1 atmosphere, 50W maximum. Figure is peak-to-peak. Output noise measurements are made across a 50MHz bandwidth using a 12 inch twisted pair, terminated with a 47F capacitor. Total regulation is defined as the static output regulation at 25C, including initial tolerance, line voltage within stated limits, load currents within stated limits and output voltages adjusted to their factory settings. For multiple output units to maintain stated regulation then: 0.25 IA / IB 5, for IB > 0.3A 0.50 IA / IB 5, for IB < 0.3A Minimum load must also be 4W to achieve design MTBF. For maximum output current IC on triple-output models, i.e. for: IC = IMax., then IA min. 0.5A and IB IC. Derating curve is application specific for ambient temperatures >50C, for optimum reliability, no part of the heatsink should exceed 120C, and no semiconductor case temperature should exceed 130C. Caution: allow a minimum of 1 second after disconnecting line power when making thermal measurements. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product.
Mechanical notes
A Ground pad encircling mounting hole near P1 allows system grounding through a metal stand-off of up to 8mm max. diameter to metal chassis. B A standard L-bracket and cover is available for mounting, which contains all screws, connectors and necessary mounting hardware. Order part number `NAL40 COVER KIT'.
3 4
5
5.00 (127.00) 0.156 (3.96) Dia. (4 Places)
J2 F1 F3.15A, 250VAC 1
6
3.00 (76.20) T1 1 J1 P1 0.22 (5.59) 4.55 (115.80)
2.55 (64.80)
7 8
MAXIMUM COMPONENT HEIGHT 1.2 inches
0.22 (5.59)
ALL DIMENSIONS IN INCHES (mm)
INPUT PIN CONNECTIONS J1 Pin 1 AC Neutral Pin 2 No Pin Pin 3 AC Line P1 Pin 1 Safety Ground
OUTPUT PIN CONNECTIONS J2 DUAL TRIPLE P1 +12V V (B) P2 +5.1V V (A) P3 +5.1V V (A) P4 Return Return P5 Return Return P6 N/C V (C)
DERATING CURVE (See Notes 6, 7) Output Power (Watts) 50W 20 CFM FORCED AIR COOLING 40W
NATURAL CONVECTION COOLING
25W 20W
4W
4W MIN. LOAD TO ACHIEVE DESIGN MTBF 20C 30C 40C 50C 60C 70C
0C 10C
Available Output Power V's Ambient Temperature
AC (J1) mating connector Molex 09-50-3031 or equiv. with Molex 08-50-0105 or equiv. crimp terminals. DC (J2) mating connector Molex 09-50-3061 or equiv. with Molex 08-50-0164 or equiv. crimp terminals.
BTO_DS_NAN40_20011119.PDF
Data Sheet (c) Artesyn Technologies(R) 2001 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
http://www.artesyn.com
PAGE 2


▲Up To Search▲   

 
Price & Availability of NAN40-7607

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X